15.4. Connection of elements of the air conditioning system

Before installation check a new sealing ring for absence of damage and oil it for conditioner compressor lubricant. Tighten bolts and nuts the required moment.


Internal elements of the cooling system are in a condition of chemical stability until reagent and oil for lubricant are used pure, without moisture. Insignificant amount of dirt, moisture and damp oil can break chemical stability of system and working capacity or to put the air conditioning system out of action.

Precautionary measures

PERFORMANCE ORDER
1. Before separation of elements of the air conditioning system it is necessary to prepare tools and devices for service of system so that to leave disconnected system elements on as smaller time is possible.
2. At separation of components of the air conditioning system immediately close connections by the corresponding covers for an exception of hit of moisture in system.
3. All spare elements and tubes of the air conditioning system have to be stored in tight packing.
4. Repeatedly do not bend earlier formed tubes.
5. All tools, the coolant distributing a collector, measuring devices and tubes have to be stored in the dry and pure place.