db57d230

4.10. SOHC engine thermostat

1 – bolt, 15–20 N • m;
2 – union of an exit of cooling liquid;
3 – laying;
4 – thermostat;
5 – thermostat casing.

Removal

PERFORMANCE ORDER
1. Merge cooling liquid to the level located below the thermostat.
2. Remove the union of an exit of cooling liquid and laying.
3. Remove the thermostat.

Check

PERFORMANCE ORDER
1. Visually check a condition of the thermostat.
2. On a thread suspend the thermostat in a transparent vessel with water.
3. Insert the thermometer into water, heat a vessel with water and watch the thermostat valve. Determine temperature of the beginning of opening and full opening of the valve of the thermostat.

Temperature began opening of the valve of the thermostat: 82 °C.
Temperature of full opening of the valve of the thermostat: 95 °C.
Thermostat valve stroke: 8,0 mm


Installation

PERFORMANCE ORDER
1. Install the thermostat so that the valve for removal of air correctly settled down in a nest. If the thermostat is installed in the wrong situation, the basis of the thermostat will touch an edge in an inlet collector that will break its working capacity.
2. Establish new laying and the union of an exit of cooling liquid.
3. Fill in necessary amount of the required cooling liquid in the cooling system. Launch the engine and check lack of leaks from the cooling system.